Strona 1 - Integrated Refrigeration

INSTALLATION GUIDEIntegrated Refrigeration

Strona 2 - Contents

Site Preparation 10An anti-tip bracket and hardware is provided with the inte-grated unit. Placement of the anti-tip bracket is critical toa stable in

Strona 3 - Before You Start

Site Preparation 11subzero.com/specsAnti-Tip Bracket InstallationINSTALL CONCRETE WEDGE ANCHORS:1) Drill a3/8" (10) diameter hole any depth excee

Strona 4 - (686) TALL MODELS

Integrated Installation 12Position the UnitPlug the power cord into the grounded electrical outlet.With power applied to the appliance, check for ligh

Strona 5 - (914) TALL MODELS

Integrated Installation 13subzero.com/specsMolding InstallationInstall the decorative white molding strips to the top andsides of the integrated unit

Strona 6 - Overall Dimensions

Integrated Installation 14MOUNTINGBRACKETKickplate/grille installation.Kickplate/Grille InstallationOnce the integrated unit is secured, the kickplate

Strona 7 - Opening Dimensions

Integrated Installation 15subzero.com/specsPanel dimensions are based on a1/8" (3) reveal. A reveal of upto1/4" (6) is possible with adjustm

Strona 8 - Electrical Requirements

Integrated Installation 16Panel ConsiderationsDOOR PANEL HEIGHTThe height of the door panel can extend beyond thetypical panel height, provided you do

Strona 9 - Plumbing Requirements

Integrated Installation 17subzero.com/specsPanel InstallationDOOR PANEL INSTALLATIONRemove the two pieces of mounting hardware attached tothe front of

Strona 10 - Anti-Tip Bracket Installation

Integrated Installation 18Panel InstallationPANEL BRACKET POSITIONINGThe illustrations below show placement of panel mountingbrackets. Dimensions are

Strona 11 - Position the Unit

With the two mounting brackets in place, install thedrawer panel by engaging the top tabbed bracket first,then slide the lower L-bracket onto the posi

Strona 12 - Level the Unit

Important NoteTo ensure the safe and efficient installation of Sub-Zeroequipment, please take note of the following types ofhighlighted information th

Strona 13 - Molding Installation

Integrated Installation 2090° door stop.Dual InstallationsTwo integrated units may be placed side by side in a dualinstallation. Panel width dimension

Strona 14 - Panel Considerations

Integrated Installation 21Installation ChecklistTo ensure a safe and proper installation, the followingchecklist should be completed by the installer

Strona 15 - TYPICAL PANEL DIMENSIONS

Service Information 22Service InformationIf service is necessary, maintain the quality built into yourintegrated unit by calling Sub-Zero factory cert

Strona 16 - TOE KICK CLEARANCE

The information and images in this guide are the copyright property of Sub-Zero, Inc. Neither this guide nor any information or images contained herei

Strona 17 - Panel Installation

SUB-ZERO, INC. P. O. BOX 44848 MADISON, WI 53744 SUBZERO.COM 800.222.78207023602 REV-A 12/2011

Strona 18 - PANEL BRACKET POSITIONING

Sub-Zero Integrated RefrigerationThe importance of the installation of the Sub-Zerointegrated unit cannot be overemphasized. Installationshould be don

Strona 19 - L BRACKET

Model Specifications 4MODELS IC-27R AND IC-27FI27" (686)14"(356)15/8"(41)24"(610)81"(2057)TO TOP OFOPENNG24" (610)789/16

Strona 20 - Typical Panel Dimensions

Model Specifications 5subzero.com/specsMODELS 736TR, 736TFI AND 736TCI36" (914)14"(356)80"(2032)TO TOP OFOPENNG24" (610)15/16"

Strona 21 - Installation Checklist

Model Specifications 6Shipping Weight lbs (kg)IC-27R, IC-27FI, 700TR, 700TFI and 700TCI 360 (163)736TR, 736TFI and 736TCI 480 (218)700BR, 700BF(I) and

Strona 22 - Service Information

Site Preparation 7subzero.com/specsIMPORTANT NOTE: The depth of each integrated model is24"(610)from the front of the unit to its back. Your desi

Strona 23

Site Preparation 8Electrical RequirementsThe electrical supply should be located within the shadedarea shown in the illustrations below. Follow the Na

Strona 24 - 7023602 REV-A 12/2011

Site Preparation 9subzero.com/specsPlumbing RequirementsFor integrated models with an automatic ice maker, thewater supply line should be located thro